Model | PAT-1 | PAT-2 | PAT-2E | PAT-10 |
Visual inspection | + | + | + | + |
Earth bond resistance I = 200 mA | + (0,01…19,99 Ω) | + (0,01…19,99 Ω) | + (0,01…19,99 Ω) | + (0,01…19,99 Ω) |
Earth bond resistance I = 10 A | – | – | – | + (0,001…1,99 Ω) |
Insulation resistance U = 250 V |
– | – | – | + (0,01…99,9 MΩ) |
Insulation resistance U = 500 V |
+ (0,01…99,9 MΩ) | + (0,01…99,9 MΩ) | + (0,01…99,9 MΩ) | + (0,01…99,9 MΩ) |
Alternative leakage current | + (0,01…19,9 mA) | + (0,01…19,9 mA) | + (0,01…19,9 mA) | + (0,01…19,9 mA) |
Touch leakage current | – | – | + (0,001…4,999 mA) | + (0,001…4,999 mA) |
Differential leakage current | – | – | + (0,10…19,9 mA) | + (0,10…19,9 mA) |
IEC cord test (RISO, RPE, Polarity) | + | + | + | + |
PRCD (trip time for IΔn: x1/x5; 0° and 180°) | – | – | 10 mA, 30 mA | 10 mA, 30 mA |
Built-in Memory | – | + | + | + |
WiFi | – | + | + | + |
Cooperation with printer | – | + | + | + |
Data transmition to PC | + | + | + | + |
Power supply | battery powered (+ can measure in charging mode) |
battery powered (+ can measure in charging mode) |
50 Hz (or 60Hz) U nominal. 220V.230V.240V / battery powered |
50 Hz (or 60Hz) U nominal. 220V.230V.240V / battery powered |
Measurement Category: CAT II 300V | + | + | + | + |
Weight [kg] / size [cm] | ok. 1.40 kg / 200 mm x 180 mm x 77 mm |
ok. 1.40 kg / 200 mm x 180 mm x 77 mm |
ok. 1.55 kg / 200 mm x 180 mm x 77 mm |
ok. 1.55 kg / 200 mm x 180 mm x 77 mm |
PAT CAN BE USED TO TEST THE EQUIPMENT PERFORMANCE IN ACCORDANCE WITH STANDARDS:
- PEN 60745-1 Hand-held motor-operated electric tools. Safety. General requirements
- EN 61029 Safety of transportable motor-operated electric tools – General requirements
- EN 60335-1 Household and similar electrical appliances -Safety -Part 1: General requirements
- EN 60950 Safety of information technology equipment (IT Equipment) AS/NZS 3760:2010 In-service safety inspection and testing of electrical equipment
- VDE 0404-1 Prüf – und Messeinrichtungen zum Prüfen der elektrischen Sicherheit von elektrischen Geräten. Teil 1: Allgemeine Anforderungen
- VDE 0404-2 Prüf – und Messeinrichtungen zum Prüfen der elektrischen Sicherheit von elektrischen Geräten. Teil 2: Prüfeinrichtungen für Prüfungen nach Instandsetzung, Änderung oder für Wiederholungsprüfungen
- VDE 0701-0702 Prüfung nach Instandsetzung, Änderung elektrischer Geräte. Wiederholungsprüfung elektrischer Geräte. Allgemeine Anforderungen für die elektrische Sicherheit
Reviews