(TRUE RMS) up to 1000 A.
Measurement of INRUSH current in start-up phase of electrical device (high frequency of sampling)
AC/DC voltage measurement (TRUE RMS) up to 600 V.
Resistance measurement and continuity test:
Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Duty cycle measurement.
Diode test.
Additionally:
Electric security:
Other technical data:
Rated operational conditions:
AC/DC current measurement (TRUE RMS)
Range | Resolution | Accuracy (DC) |
Accuracy (AC) |
0…659,9 A | 0,1 A | ±(2,5% m.v. +5 dgt) | ±(2,5% m.v + 8 dgt) for f=45…65 Hz |
660…1000 A | 1 A | ±(2,8% m.v. +8 dgt) | ±(2,8% m.v. + 8 dgt) for f=45…65 Hz |
DC voltage measurement
Range | Resolution | Accuracy |
0…6,599 V | 0,001 V | ±(1,5% m.v. + 3 dgt) |
6,60…65,99 V | 0,01 V | |
66,0…600,0 V | 0,1 V |
AC voltage measurement (TRUE RMS)
Range | Resolution | Accuracy |
0…6,599 V | 0,001 V | ±(1,8% m.v. + 5 dgt) for f=50…60 Hz |
6,60…65,99 V | 0,01 V | |
66,0…600,0 V | 0,1 V |
Resistance measurement
Range | Resolution | Accuracy |
0,0…659,9 Ω | 0,1 Ω | ±(1,0% m.v. + 4 dgt) |
0,660…6,599 kΩ | 0,001 kΩ | ±(1,5% m.v. + 2 dgt) |
6,60…65,99 kΩ | 0,01 kΩ | |
66,0…659,9 kΩ | 0,1 kΩ | |
0,660…6,599 MΩ | 0,001 MΩ | ±(2,5% m.v. + 3 dgt) |
6,60…66,00 MΩ | 0,01 MΩ | ±(3,5% m.v. + 5 dgt) |
Frequency measurement
Range | Resolution | Accuracy |
30,0…659,9 Hz | 0,1 Hz | ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle |
0,660…9,999 kHz | 0,001 kHz | |
6,60…15,00 kHz | 0,01 kHz |
Temperature measurement
Range | Resolution | Accuracy |
-20…760°C | 1°C | ±(3,0% m.v. + 5°C) |
-4…1400°F | 1°F | ±(3,0% m.v. + 9°F) |
Duty cycle measurement
Range | Resolution | Accuracy |
10,0…94,9% | 0,1% | ±(1,2% m.v. + 2 dgt) |
• pulse width: 100μs…100 ms,
?• frequency range: 30 Hz…15 kHz,
• sensitivity: 30 Hz…5 kHz: 10 Vrms, 5 kHz…15 kHz: 40 Vrms.
„m.v.”- measured value