MIC-10K1     

Catalog index: WMGBMIC10K1

Insulation Resistance Meter

 

               

Req quote

Insulation resistance measurement:up to 40 TΩ

  • measurement voltage any in the range of: 50…10000 V (50…1000 V at 10 V and 1…10 kV at 25 V),
  • continuous indication of measured insulation resistance or leakage current,
  • automatic discharge of measured object capacitance voltage after the end of insulation resistance measurement,
  • acoustic signaling of 5 seconds intervals to facilitate capturing time characteristics,
  • adjustable measuring time to 99’59’’,
  • metered T1, T2 and T3 test times for measuring one or two absorption coefficients from the range of 1…600 s,
  • polarization index (PI), absorption coefficients Ab1, Ab2 and dielectric absorption ratio (DAR) measurement,
  • indication of actual test voltage during measurement,
  • 1.2 mA, 3 mA and 6 mA test current,
  • Guard terminal accuracy ±2%
  • insulation resistance measurement using two- or three-wire method,
  • measurements with test leads up to 20 m…
  • protection against measuring live objects,
  • resistance to external interference voltages up to 2550V
  • automatic measurement of multiple core cables with the additional AutoISO-5000 adapter (for MIC-10k1 max. voltage 5 kV)
  • measurement of capacitance during the measurement of RISO.
  • measurement of temperature (with additional probe – WASONT1),
  • step voltage insulation resistance measurement (SV),
  • Dielectric Discharge calculation (DD),
  • location of damage (burnout),

Digital filters function for measurements in high noise environment.
Continuity measurement of protective connections and equipotential bonding in accordance with EN 61557-4 with current > 200 mA.
Adjustable limits for measured resistance RISO and RCONT.
Measurement of leakage current during insulation resistance testing.
DC and AC voltage measurement in the range of  0…750 V.
Drawing graphs on the display during measurement.
Innovative  memory  with possibility of description of:  measurement points,  facilities,  names  of  customers.
Operating with mini Bluetooth keyboard (option).
MIC-10K1 – Stable measurements in noisy environments such as 765 kV substations.
Graphic LCD 5,6’’ backlit.
Keyboard backlit.
Power supply from battery packs.
Built-in fast charger.
The instruments meet the requirements of the EN 61557 standard.

Insulation resistance measurement MIC-10K1
easurement range acc. to IEC 61557-2: UN = 10000V: 10,0MΩ…40,0TΩ

Range Resolution Accuracy
0,0…999 kΩ 1 kΩ ±(3% m.v. + 10 digits)
1,00…9,99 MΩ 0,01 MΩ
10,0…99,9 MΩ 0,1 MΩ
100…999 MΩ 1 MΩ
1,00…9,99 GΩ 0,01 GΩ
10,0…99,9 GΩ 0,1 GΩ
100…999 GΩ 1 GΩ ±(3,5% m.v. + 10 digits)
1,00…9,99 TΩ 0,01 TΩ ±(7,5% m.v. + 10 digits)
10,0…20,0 TΩ 0,1 TΩ ±(12,5% m.v. + 10 digits)
10,0…40,0 TΩ

Values of measured resistance depending on measurement voltage

Voltage UISO Measurement
range
AutoISO-5000
measurement range
50 V 200 GΩ 20,0 GΩ
100 V 400 GΩ 40,0 GΩ
250 V 1,00 TΩ 100 GΩ
500 V 2,00 TΩ 200 GΩ
1000 V 4,00 TΩ 400 GΩ
2500 V 10,00 TΩ 400 GΩ
5000 V 20,0 TΩ 400 GΩ
10 000 V 40,0 TΩ

Step voltage insulation resistance measurement

Voltage UISO MIC-10k1
50…1000 V 10 V
1000…5000 V 25 V
5000…10000 V 25 V

Resistance to External Interference Voltage up to 2550V

Continuity measurement of protective connections and equipotential bonding with 200 mA current
Measurement range acc. to EN 61557-4: 0,12…999 Ω

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(2%m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω
200…999 Ω 1 Ω ±(4%m.v. + 3 digits)
  • Voltage on open terminals:  4…24 V
  • Output current at R  < 15 Ω: min. 200 mA (ISC: 200…250 mA)
  • Compensation of test lead resistance
  • Current flowing in both directions, mean value of resistance is displayed

DC and AC voltage measurement

Range Resolution Accuracy
0.0…29,9 V 0,1 V ±(2% m.v. + 20 digits)
30,0…299,9 V 0,1 V ±(2%m.v. + 6 digits)
300…750 V 1 V ±(2% m.v. + 2 digits)
  • Frequency range: 45…65Hz

Measurement of capacitance

Display range Resolution Accuracy
1…999 nF 1 nF ±(5%m.v. + 5 digits)
1,00…49,99 µF 0,01 µF
  • capacity measurement result is displayed after the RISO measurement
  • for measuring voltages under 100 V capacitance measurement accuracy not specified.

Measurement of temperature

Display range Resolution Accuracy
-40,0…99,9 °C 1 °C ±(3%m.v. + 8 digits)
-40,0…211,8 °F 1 °F ±(3%m.v. + 16 digits)

Electrical safety of MIC-10K1:

  • type of insulation: double, in acc. with EN 61010-1 and IEC 61557
  • measurement category: IV 600 V (III 1000 V) in acc. with  EN 61010-1
  • case protection rating in acc. with  EN 60529: IP40 (IP67 – with lid closed)

Other technical specifications of MIC-10K1:

  • power supply of the meter: built-in battery pack,
  • weight of the meter: approx. 5,6 kg,
  • dimensions: 390 x 310 x 180 mm,
  • display: graphic LCD 5,6′,
  • transmission of measurement results USB or Bluetooth®.

The acronym “m.v.” stands for a “measured reference value”.

Data Sheet                                      

User Manual                                   

Declarations of conformity          

Firmware for MIC-10K1