The P4i is an easy to use all-in-one solution for troubleshooting, pre-locating and pinpointing of cable faults in complex LV, lighting and control cable networks. Menu guided computerised operation allows to detect and precisely locate various faults for even unexperienced users. Featuring a large colour screen, the P4i can display measurement curves, test results and message codes simultaneously. This complete system includes a precise DC HV test facility that measures and displays leakage current over time. Integrated full scale TDR capability in combination with the high voltage
arc reflection mode (ARTi) will isolate and pre-locate low as well as high resistance faults with utmost precision. As a result precise pinpointing will take much less time. The fast HV surge pulse cycles of 3 sec. with up to 1000 Joule energy support the most demanding locating jobs while the multi-dimensional safety system ensures maximum safety for instrument and operator. The optional pinpointer Kamphone and Locator S are used for flash-over faults or cable sheath faults respectively. As an economic alternative, the version P4e is available without integrated TDR and ARTi.
APPLICATIONS & FEATURES
SAFETY FEATURES:
STANDARD:
OPTIONAL:
Analysis & test of faults: | |
IRM mode (opt.) | 10kΩ to 200MΩ @ 5kV |
HV DC mode | 0 to 6kV |
Isolation of faults: | |
TDR range | 60km |
TDR impulse / widths | 160V / 50ns to 10µs |
TDR resolution | 0,2m |
TDR impedance matching | 25 to 1600Ω |
Pre-location TDR-LV mode | 1-phase over HV cable |
Optional | 3-phase over LV cable |
Optional | Intermittent Fault Scanning |
Pre-location TDR-HV mode | ARTi: 4kV (Arc Reflection) |
Optional | SCC: 4kV (Surge Current) |
Fault conditioning | 400mA |
Optional | 1,4A |
Mapping of faults: | |
Surge mode | 0 to 4kV; 1000J |
Surge mode pulse range | 3s to 10s; single shot |
Sheath pinpointing (opt.) | 0 to 4kV |
GENERAL DATA | PROSAFE 3D or 5D system |
Safety | |
Dimensions | 297 x 516 x 620mm |
IP rating | IP43 |
Weight | 57kg |
Mains supply | 230V, 50Hz |
Operating temperature | -10°C to +55°C |
SCOPE OF SUPPLY
P4i (Basic)
Set of connection cables (5m) incl. cable bag
FU/EP sensor kiT
User manual on CD
OPTIONS
Pinpointer: Kamphone & Locator S
Standard Trolley
Rugged Version (IP54) with rugged Trolley
Connection Kits: 25m or 50m (HV+LV)
P4e without TDR and ARTi